How do I extend the stem for a 01series trim faucet?

Rate This Faq
 
 

910-005

To add stem extension assembly to Hot and Cold valves, remove handle trim and flanges. Please refer to your instruction manual for directions.

1)     Remove stop (4). Please note notch (7) location when removing stop. (See Detail 1A).

2)     Carefully thread sleeve extension (6) onto valve (5).

3)     Replace stop (4) making sure that notch (7) is facing backwards. Align flat inside of stop (4) with missing tooth on the spline (8). (See Detail 1A).

4)     Attach stem extension (2) onto stem (1) and thread adapter screw (3) through stem extension (2) and into stem (1).

5)     Wrench tighten adapter screw (3).

NOTE: Stem extension (2) can be shortened by ½” by cutting through it at the scribed mark (12). Please refer to instruction manual for directions to reinstall flanges and handle trim.

 

To add stem extension assembly to Diverter valve remove handle trim and flange. Please refer to instruction manual for directions.

  1. Thread nut adapter (9) into packing nut (10). Wrench tighten Nut adapter (9).
  2. Attach stem extension (2) onto stem (11) and thread adapter screw (3) through stem extension (2) and into stem (11).
  3. Wrench tighten adapter screw (3).

Documents